Solid State Relay with a fieldbus Interface : Make the most of your SSR

ECOM0010 combined with our SU/SUL is a compact solution providing a communication interface, a current monitoring and a PID temperature controller.

The ECOM is the most compact solution available on the market that incorporates the latest measuring and control technology.
By reducing wiring costs and minimizing the size of electrical cabinets, this solution is the answer to your needs.

SSR with a fieldbus Interface

Here are the main features of our Optional Module ECOM :


1-Communication Interface

Real-time monitoring

 

 


Our ECOM allows a Real-time monitoring via an RS485 link and MODBUS RTU protocol.

Modbus RTU is an open serial protocol derived from the Master/Slave architecture originally developed by Modicon (now Schneider Electric). It is a widely accepted serial level protocol due to its ease of use and reliability. Modbus RTU is widely used within Building Management Systems (BMS) and Industrial Automation Systems (IAS).

ECOM optional module

A Direct control is possible by HMI or PLC with MODBUS RTU protocol.

Other communication protocols are possible (e.g. Ethernet IP, Ethercat, Profinet…) through a Modbus RTU converter Gateway.


2-Load status and relay diagnostics

Load statusrelay diagnostics

3-PWM mode to control load power

PWM control

Pulse width modulation (PWM) is a great method of controlling the amount of power delivered to a load without dissipating any wasted power.
The duty cycle and cycle time can be set-up via the communication interface.
Logic outputs OUT1 and OUT2 can be used to control another Solid State Relay.


4-Current monitoring and alarms up to 50A with current transformer

Current monitoring and alarms

5-Temperature measurement, PID control and alarms

Temperature measurement

• The thermocouple is a simple, widely used component for measuring temperature. An Insulated input is available for thermocouples type J, K, T, E.

• Logic outputs OUT1 and OUT2 of the ECOM module can be used for heating and cooling.

• PID with automatic or manual tuning :
Automatic tuning will always be active and will constantly analyse the difference setpoint-process (error). If this difference is greater than the value selected on parameter 7 (Max Gap Tune), the ECOM will decide when and how to modify PID parameters.
The manual procedure allows the user a greater !exibility on deciding when to update PID algorithm parameters.

Celpac 2G : Your avant-garde 22.5 mm SSR solution !